{"id":2101,"date":"2020-07-21T13:17:00","date_gmt":"2020-07-21T17:17:00","guid":{"rendered":"https:\/\/pressbooks.bccampus.ca\/chbe220\/?post_type=chapter&#038;p=2101"},"modified":"2020-08-13T12:26:25","modified_gmt":"2020-08-13T16:26:25","slug":"process-control-and-safety-pr","status":"publish","type":"chapter","link":"https:\/\/pressbooks.bccampus.ca\/chbe220\/chapter\/process-control-and-safety-pr\/","title":{"raw":"Practice Exercises","rendered":"Practice Exercises"},"content":{"raw":"<div class=\"textbox textbox--exercises\"><header class=\"textbox__header\">\r\n<p class=\"textbox__title\">Exercise: Safety Action<\/p>\r\n\r\n<\/header>\r\n<div class=\"textbox__content\">\r\n\r\nDuring a yearly safety assessment, you find that a pressure relief valve in a heat exchanger is rusted and may not open properly in case of a pressure build-up. What is the best course of action?\r\n\r\na)<span style=\"font-size: 1em\">\u00a0<\/span><span style=\"font-size: 1em\">Report to the project manager and immediately replace the pressure relief valve<\/span>\r\n\r\nb) Operate the process at a lower pressure to reduce the risk of over-pressurizing\r\n\r\nc) Ignore it because the probability of over-pressurizing is very low\r\n\r\n<\/div>\r\n<\/div>\r\n<div class=\"textbox\">\r\n<h3>Solution<\/h3>\r\n<strong>a) Report to the project manager and immediately replace the pressure relief valve\r\n<\/strong>Any safety hazard should be reported and addressed as soon as possible.\r\nFor b), Operating the process at a lower pressure does not completely eliminate risks and may reduce process efficiency. In the long run, this will cost more than a new pressure relief valve.\r\n\r\n<\/div>\r\n<div><\/div>\r\n<div class=\"textbox textbox--exercises\"><header class=\"textbox__header\">\r\n<p class=\"textbox__title\">Exercise: OSHA Incident Rate for Exposure to Hazardous Materials<\/p>\r\n\r\n<\/header>\r\n<div class=\"textbox__content\">\r\n\r\nSuppose that a total of\u00a0 12 operators have been exposed to leaking hazardous materials <span style=\"font-size: 1em\">in a chemical plant<\/span><span style=\"text-align: initial;font-size: 1em\">. The total working hours that might expose the workers to the risk <\/span><span style=\"text-align: initial;font-size: 1em\">are 870,000 hours. Calculate the OSHA incident rate for exposure to hazardous materials.\u00a0<\/span>\r\n\r\n<\/div>\r\n<\/div>\r\n<div class=\"textbox\">\r\n<h3>Solution<\/h3>\r\n\\begin{align*}\r\n\\text{incident rate} &amp; = \\frac{\\text{number of incident exposure}\u00d7200,000}{\\text{number of working hours}}\\\\\r\n&amp; =\\frac{12\u00d7200,000}{870,000}\\\\\r\n&amp; = 2.76\r\n\\end{align*}\r\n\r\n<\/div>\r\n&nbsp;\r\n<div>\r\n<div class=\"textbox textbox--exercises\"><header class=\"textbox__header\">\r\n<p class=\"textbox__title\">Exercise: Pump Kickback Loop<\/p>\r\n\r\n<\/header>\r\n<div class=\"textbox__content\">\r\n\r\nSometimes a kickback loop is added on a pump to prevent damage to the pump when the outlet stream is blocked:\r\n\r\n<img class=\"size-medium wp-image-2112 aligncenter\" src=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-no-kickback-loop-300x163.png\" alt=\"\" width=\"300\" height=\"163\" \/>\r\n\r\n<img class=\" wp-image-2113 aligncenter\" src=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-kickback-loop-300x129.png\" alt=\"\" width=\"521\" height=\"224\" \/>\r\n\r\nCompare the effect between the kickback loop is present or not when we close the valve (or when the stream after the valve is blocked), explain how the kickback loop prevents damage.\r\n\r\n<\/div>\r\n<\/div>\r\n<div class=\"textbox\">\r\n<h3>Solution<\/h3>\r\nIf no kickback loop present, the pump keeps doing work on the liquid before the valve, but the stream is not able to move forward. As a result, the stream will be heated up. If the stream vapourizes, the vapour may tear up the metal blade in the pump.\r\n\r\nWhen there is a backflush cycle, the stream will circulate in the kickback loop, which increases the amount of liquid pumped and dissipates the heat.\r\n\r\n<\/div>\r\n<div class=\"textbox textbox--exercises\"><header class=\"textbox__header\">\r\n<p class=\"textbox__title\">Exercise: HCl Production What-if Analysis<\/p>\r\n\r\n<\/header>\r\n<div class=\"textbox__content\">\r\n\r\nShown below is the simplified process of HCl production\r\n\r\n<img class=\" wp-image-2153 aligncenter\" src=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-HCl-production-new-300x142.png\" alt=\"\" width=\"606\" height=\"287\" \/>\r\n\r\nThe following reaction happens in the reactor at a temperature of 900\u00b0C:\r\n<p style=\"text-align: center\">[latex]H_{2(g)}+Cl_{2(g)}\\rightarrow 2HCl_{(g)}\\;\\;\\;\\;\\;\\Delta H=-92.3kJ\/mol[\/latex]<\/p>\r\nIn the absorber, HCl gas is dissolved in a water stream ([latex]\\Delta H[\/latex] of solution = -74.8 kJ\/mol), producing aqueous HCl solution\r\n\r\nPerform what-if analysis regarding the following scenarios:\r\n\r\na) What if the cooling water stream in the reactor is blocked? State the direct consequences and recommendations.\r\n\r\nb) If the cooling water stream in the absorber is blocked, how would the concentration of the product be affected?\r\n\r\n<\/div>\r\n<\/div>\r\n<div class=\"textbox\">\r\n<h3>Solution<\/h3>\r\na) If the cooling water stream is blocked, the temperature in the reactor will rise up due to the exothermic reaction. The gas in the reactor will expand, which leads to pressure increase and potential explosion.\r\nRegular maintenance should be performed and a pressure relief valve should be installed in the reactor.\r\n\r\nb) The absorber heats up as the process of HCl dissolving is exothermic. As the temperature increases, the solubility of HCl decreases, which leads to a lower concentration of HCl in the product.\r\n\r\n<\/div>\r\n&nbsp;\r\n<div class=\"textbox textbox--exercises\"><header class=\"textbox__header\">\r\n<p class=\"textbox__title\">Exercise: Glycerol Purification<\/p>\r\n\r\n<\/header>\r\n<div class=\"textbox__content\">\r\n\r\nWe use a distillation column to purify a stream of glycerol with methanol impurities:\r\n<table class=\"grid aligncenter\" style=\"border-collapse: collapse;width: 100%\" border=\"0\">\r\n<tbody>\r\n<tr>\r\n<td style=\"width: 50%\"><\/td>\r\n<td style=\"width: 50%\"><strong>Boiling Point (\u00b0C) at 1 atm<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 50%\">Glycerol<\/td>\r\n<td style=\"width: 50%\">290<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 50%\">Methanol<\/td>\r\n<td style=\"width: 50%\">65<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<img class=\" wp-image-2111 aligncenter\" src=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-distillation-column-1-300x171.png\" alt=\"\" width=\"475\" height=\"271\" \/>\r\n\r\nBase on the given information, answer the following questions:\r\n\r\na) What is the major component in stream 1 &amp; 2?\r\n\r\nb) Draw a control loop that regulates the rate of separation by controlling the level of the liquid in the column.\r\n\r\nc) If the level in the column is too high, is the valve in the control loop open or closed?\r\n\r\nd) Is there any safety hazard if valve V-102 fails closed?\r\n\r\n<\/div>\r\n<\/div>\r\n<div class=\"textbox\">\r\n<h3>Solution<\/h3>\r\n<strong>a)<\/strong> Stream 1 is majorly methanol and Stream 2 is majorly glycerol.\r\nSince methanol has a much lower boiling point than glycerol, methanol will mostly be in the vapour phase and glycerol will mostly be in the liquid phase when an appropriate temperature is selected for the distillation column.\r\n<div class=\"textbox shaded\"><strong>How do we know Stream 1 is the vapour stream and Stream 2 is the liquid stream?\r\n<\/strong>1. Since vapour is lighter the liquid, vapour will exit at the top of the column and liquid will exit at the bottom\r\n2. Pumps can only be used on liquid streams\r\n3. The reboiler loop is on the liquid stream. It vapourizes part of the liquid and sends it back into the column to increase the rate of separation<\/div>\r\n<strong>\u00a0b)\u00a0<\/strong><strong><img class=\" wp-image-2110 aligncenter\" src=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-distillation-column-level-control-300x173.png\" alt=\"\" width=\"550\" height=\"317\" \/>\r\nc)\u00a0<\/strong>The valve in the control loop will be open. Because the valve is on the outlet of the liquid stream, opening the valve increases the flow of the liquid stream out of the column, decreasing the liquid level in the column.\r\n\r\n<strong>d)\u00a0<\/strong>There is no safety hazard, but it leads to ineffective separation.\r\nWhen V-102 fails open all the liquid will be sent back into the column as vapour, which shifts the vapour-liquid equilibrium in the column.\r\n\r\n<\/div>\r\n<div class=\"textbox textbox--exercises\"><header class=\"textbox__header\">\r\n<p class=\"textbox__title\">Exercise: Nitric Acid Production<\/p>\r\n\r\n<\/header>\r\n<div class=\"textbox__content\">\r\n\r\nThe following diagram shows the major process steps for the production of nitric acid.<img class=\" wp-image-2160 aligncenter\" src=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-HCl-production-1-300x139.png\" alt=\"\" width=\"663\" height=\"307\" \/>\r\n\r\nAir and ammonia are first sent to a boiler where the reaction produces nitric oxide, water vapor, and heat. The process stream is then cooled through a heat exchanger, where nitric oxide oxidizes into nitric acid as temperature decreases. The first stream used in the first heat exchanger is also used as a utility stream to absorb excess heat in the boiler and convert it into energy when going through a turbine. The process stream is then sent to an absorber where it is mixed with a stream of water to produce liquid nitrate acid. The liquid acid is sent to further purification processes while the vapour produced in the absorber is sent to waste treatment.\r\n\r\na) What are the direct consequences if stream 5 is blocked? Analyze the effect on the process in the [latex]NH_{3}[\/latex] boiler and the first heat exchanger.\r\n\r\nb) Using the description in the next paragraph, build a fault-tree analysis logic diagram on the risk of severe overpressure that could lead to an explosion in the absorber, and calculate the frequencies of all events in the diagram. <span style=\"text-align: initial;font-size: 1em\">Assuming all events with given frequencies are basic events.\u00a0<\/span>\r\n\r\n<strong>Severe overpressure that could lead to an explosion\u00a0<\/strong>happens when both <strong>system over maximum pressure <\/strong>and <strong>pressure relief valve fails<\/strong> happen at the same time. <strong>System over maximum pressure<\/strong>\u00a0happens when the <strong>cooling water inlet is blocked (frequency = 0.015) <\/strong>or <strong>process vapour outlet stream is blocked (frequency = 0.008).\u00a0 Pressure relief valve fails <\/strong>happens when any one of the following circumstances happens: <strong>valve leaking (frequency=0.023)<\/strong>, <strong>valve calibrated at a wrong pressure (frequency=0.005)<\/strong>, or <strong>contaminants causing the valve to stick (frequency = 0.056)<\/strong>.\r\n\r\n<\/div>\r\n<\/div>\r\n<div class=\"textbox\">\r\n<h3>Solution<\/h3>\r\na) The process stream in the heat exchanger will not be sufficiently cooled down, so the conversion to nitric acid will be lower, decreasing the concentration of the product in the absorber.\r\nThere will not be enough flow to absorb the heat in the boiler, which will lead to a temperature increase, pressure build-up and potential explosion of the gas in the boiler.\r\nb)<img class=\"alignnone wp-image-2147\" src=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-absorber-fault-tree-300x186.png\" alt=\"\" width=\"702\" height=\"436\" \/>\r\n\r\n<\/div>\r\n&nbsp;\r\n\r\n<\/div>","rendered":"<div class=\"textbox textbox--exercises\">\n<header class=\"textbox__header\">\n<p class=\"textbox__title\">Exercise: Safety Action<\/p>\n<\/header>\n<div class=\"textbox__content\">\n<p>During a yearly safety assessment, you find that a pressure relief valve in a heat exchanger is rusted and may not open properly in case of a pressure build-up. What is the best course of action?<\/p>\n<p>a)<span style=\"font-size: 1em\">\u00a0<\/span><span style=\"font-size: 1em\">Report to the project manager and immediately replace the pressure relief valve<\/span><\/p>\n<p>b) Operate the process at a lower pressure to reduce the risk of over-pressurizing<\/p>\n<p>c) Ignore it because the probability of over-pressurizing is very low<\/p>\n<\/div>\n<\/div>\n<div class=\"textbox\">\n<h3>Solution<\/h3>\n<p><strong>a) Report to the project manager and immediately replace the pressure relief valve<br \/>\n<\/strong>Any safety hazard should be reported and addressed as soon as possible.<br \/>\nFor b), Operating the process at a lower pressure does not completely eliminate risks and may reduce process efficiency. In the long run, this will cost more than a new pressure relief valve.<\/p>\n<\/div>\n<div><\/div>\n<div class=\"textbox textbox--exercises\">\n<header class=\"textbox__header\">\n<p class=\"textbox__title\">Exercise: OSHA Incident Rate for Exposure to Hazardous Materials<\/p>\n<\/header>\n<div class=\"textbox__content\">\n<p>Suppose that a total of\u00a0 12 operators have been exposed to leaking hazardous materials <span style=\"font-size: 1em\">in a chemical plant<\/span><span style=\"text-align: initial;font-size: 1em\">. The total working hours that might expose the workers to the risk <\/span><span style=\"text-align: initial;font-size: 1em\">are 870,000 hours. Calculate the OSHA incident rate for exposure to hazardous materials.\u00a0<\/span><\/p>\n<\/div>\n<\/div>\n<div class=\"textbox\">\n<h3>Solution<\/h3>\n<p>\\begin{align*}<br \/>\n\\text{incident rate} &amp; = \\frac{\\text{number of incident exposure}\u00d7200,000}{\\text{number of working hours}}\\\\<br \/>\n&amp; =\\frac{12\u00d7200,000}{870,000}\\\\<br \/>\n&amp; = 2.76<br \/>\n\\end{align*}<\/p>\n<\/div>\n<p>&nbsp;<\/p>\n<div>\n<div class=\"textbox textbox--exercises\">\n<header class=\"textbox__header\">\n<p class=\"textbox__title\">Exercise: Pump Kickback Loop<\/p>\n<\/header>\n<div class=\"textbox__content\">\n<p>Sometimes a kickback loop is added on a pump to prevent damage to the pump when the outlet stream is blocked:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-2112 aligncenter\" src=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-no-kickback-loop-300x163.png\" alt=\"\" width=\"300\" height=\"163\" srcset=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-no-kickback-loop-300x163.png 300w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-no-kickback-loop-65x35.png 65w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-no-kickback-loop-225x122.png 225w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-no-kickback-loop-350x190.png 350w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-no-kickback-loop.png 503w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-2113 aligncenter\" src=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-kickback-loop-300x129.png\" alt=\"\" width=\"521\" height=\"224\" srcset=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-kickback-loop-300x129.png 300w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-kickback-loop-768x329.png 768w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-kickback-loop-65x28.png 65w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-kickback-loop-225x97.png 225w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-kickback-loop-350x150.png 350w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-kickback-loop.png 837w\" sizes=\"auto, (max-width: 521px) 100vw, 521px\" \/><\/p>\n<p>Compare the effect between the kickback loop is present or not when we close the valve (or when the stream after the valve is blocked), explain how the kickback loop prevents damage.<\/p>\n<\/div>\n<\/div>\n<div class=\"textbox\">\n<h3>Solution<\/h3>\n<p>If no kickback loop present, the pump keeps doing work on the liquid before the valve, but the stream is not able to move forward. As a result, the stream will be heated up. If the stream vapourizes, the vapour may tear up the metal blade in the pump.<\/p>\n<p>When there is a backflush cycle, the stream will circulate in the kickback loop, which increases the amount of liquid pumped and dissipates the heat.<\/p>\n<\/div>\n<div class=\"textbox textbox--exercises\">\n<header class=\"textbox__header\">\n<p class=\"textbox__title\">Exercise: HCl Production What-if Analysis<\/p>\n<\/header>\n<div class=\"textbox__content\">\n<p>Shown below is the simplified process of HCl production<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-2153 aligncenter\" src=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-HCl-production-new-300x142.png\" alt=\"\" width=\"606\" height=\"287\" srcset=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-HCl-production-new-300x142.png 300w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-HCl-production-new-1024x484.png 1024w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-HCl-production-new-768x363.png 768w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-HCl-production-new-65x31.png 65w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-HCl-production-new-225x106.png 225w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-HCl-production-new-350x165.png 350w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-HCl-production-new.png 1398w\" sizes=\"auto, (max-width: 606px) 100vw, 606px\" \/><\/p>\n<p>The following reaction happens in the reactor at a temperature of 900\u00b0C:<\/p>\n<p style=\"text-align: center\">[latex]H_{2(g)}+Cl_{2(g)}\\rightarrow 2HCl_{(g)}\\;\\;\\;\\;\\;\\Delta H=-92.3kJ\/mol[\/latex]<\/p>\n<p>In the absorber, HCl gas is dissolved in a water stream ([latex]\\Delta H[\/latex] of solution = -74.8 kJ\/mol), producing aqueous HCl solution<\/p>\n<p>Perform what-if analysis regarding the following scenarios:<\/p>\n<p>a) What if the cooling water stream in the reactor is blocked? State the direct consequences and recommendations.<\/p>\n<p>b) If the cooling water stream in the absorber is blocked, how would the concentration of the product be affected?<\/p>\n<\/div>\n<\/div>\n<div class=\"textbox\">\n<h3>Solution<\/h3>\n<p>a) If the cooling water stream is blocked, the temperature in the reactor will rise up due to the exothermic reaction. The gas in the reactor will expand, which leads to pressure increase and potential explosion.<br \/>\nRegular maintenance should be performed and a pressure relief valve should be installed in the reactor.<\/p>\n<p>b) The absorber heats up as the process of HCl dissolving is exothermic. As the temperature increases, the solubility of HCl decreases, which leads to a lower concentration of HCl in the product.<\/p>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"textbox textbox--exercises\">\n<header class=\"textbox__header\">\n<p class=\"textbox__title\">Exercise: Glycerol Purification<\/p>\n<\/header>\n<div class=\"textbox__content\">\n<p>We use a distillation column to purify a stream of glycerol with methanol impurities:<\/p>\n<table class=\"grid aligncenter\" style=\"border-collapse: collapse;width: 100%\">\n<tbody>\n<tr>\n<td style=\"width: 50%\"><\/td>\n<td style=\"width: 50%\"><strong>Boiling Point (\u00b0C) at 1 atm<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%\">Glycerol<\/td>\n<td style=\"width: 50%\">290<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%\">Methanol<\/td>\n<td style=\"width: 50%\">65<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-2111 aligncenter\" src=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-distillation-column-1-300x171.png\" alt=\"\" width=\"475\" height=\"271\" srcset=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-distillation-column-1-300x171.png 300w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-distillation-column-1-768x439.png 768w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-distillation-column-1-65x37.png 65w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-distillation-column-1-225x129.png 225w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-distillation-column-1-350x200.png 350w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-distillation-column-1.png 805w\" sizes=\"auto, (max-width: 475px) 100vw, 475px\" \/><\/p>\n<p>Base on the given information, answer the following questions:<\/p>\n<p>a) What is the major component in stream 1 &amp; 2?<\/p>\n<p>b) Draw a control loop that regulates the rate of separation by controlling the level of the liquid in the column.<\/p>\n<p>c) If the level in the column is too high, is the valve in the control loop open or closed?<\/p>\n<p>d) Is there any safety hazard if valve V-102 fails closed?<\/p>\n<\/div>\n<\/div>\n<div class=\"textbox\">\n<h3>Solution<\/h3>\n<p><strong>a)<\/strong> Stream 1 is majorly methanol and Stream 2 is majorly glycerol.<br \/>\nSince methanol has a much lower boiling point than glycerol, methanol will mostly be in the vapour phase and glycerol will mostly be in the liquid phase when an appropriate temperature is selected for the distillation column.<\/p>\n<div class=\"textbox shaded\"><strong>How do we know Stream 1 is the vapour stream and Stream 2 is the liquid stream?<br \/>\n<\/strong>1. Since vapour is lighter the liquid, vapour will exit at the top of the column and liquid will exit at the bottom<br \/>\n2. Pumps can only be used on liquid streams<br \/>\n3. The reboiler loop is on the liquid stream. It vapourizes part of the liquid and sends it back into the column to increase the rate of separation<\/div>\n<p><strong>\u00a0b)\u00a0<\/strong><strong><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-2110 aligncenter\" src=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-distillation-column-level-control-300x173.png\" alt=\"\" width=\"550\" height=\"317\" srcset=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-distillation-column-level-control-300x173.png 300w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-distillation-column-level-control-768x444.png 768w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-distillation-column-level-control-65x38.png 65w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-distillation-column-level-control-225x130.png 225w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-distillation-column-level-control-350x202.png 350w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-distillation-column-level-control.png 981w\" sizes=\"auto, (max-width: 550px) 100vw, 550px\" \/><br \/>\nc)\u00a0<\/strong>The valve in the control loop will be open. Because the valve is on the outlet of the liquid stream, opening the valve increases the flow of the liquid stream out of the column, decreasing the liquid level in the column.<\/p>\n<p><strong>d)\u00a0<\/strong>There is no safety hazard, but it leads to ineffective separation.<br \/>\nWhen V-102 fails open all the liquid will be sent back into the column as vapour, which shifts the vapour-liquid equilibrium in the column.<\/p>\n<\/div>\n<div class=\"textbox textbox--exercises\">\n<header class=\"textbox__header\">\n<p class=\"textbox__title\">Exercise: Nitric Acid Production<\/p>\n<\/header>\n<div class=\"textbox__content\">\n<p>The following diagram shows the major process steps for the production of nitric acid.<img loading=\"lazy\" decoding=\"async\" class=\"wp-image-2160 aligncenter\" src=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-HCl-production-1-300x139.png\" alt=\"\" width=\"663\" height=\"307\" srcset=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-HCl-production-1-300x139.png 300w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-HCl-production-1-1024x473.png 1024w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-HCl-production-1-768x355.png 768w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-HCl-production-1-65x30.png 65w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-HCl-production-1-225x104.png 225w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-HCl-production-1-350x162.png 350w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-HCl-production-1.png 1368w\" sizes=\"auto, (max-width: 663px) 100vw, 663px\" \/><\/p>\n<p>Air and ammonia are first sent to a boiler where the reaction produces nitric oxide, water vapor, and heat. The process stream is then cooled through a heat exchanger, where nitric oxide oxidizes into nitric acid as temperature decreases. The first stream used in the first heat exchanger is also used as a utility stream to absorb excess heat in the boiler and convert it into energy when going through a turbine. The process stream is then sent to an absorber where it is mixed with a stream of water to produce liquid nitrate acid. The liquid acid is sent to further purification processes while the vapour produced in the absorber is sent to waste treatment.<\/p>\n<p>a) What are the direct consequences if stream 5 is blocked? Analyze the effect on the process in the [latex]NH_{3}[\/latex] boiler and the first heat exchanger.<\/p>\n<p>b) Using the description in the next paragraph, build a fault-tree analysis logic diagram on the risk of severe overpressure that could lead to an explosion in the absorber, and calculate the frequencies of all events in the diagram. <span style=\"text-align: initial;font-size: 1em\">Assuming all events with given frequencies are basic events.\u00a0<\/span><\/p>\n<p><strong>Severe overpressure that could lead to an explosion\u00a0<\/strong>happens when both <strong>system over maximum pressure <\/strong>and <strong>pressure relief valve fails<\/strong> happen at the same time. <strong>System over maximum pressure<\/strong>\u00a0happens when the <strong>cooling water inlet is blocked (frequency = 0.015) <\/strong>or <strong>process vapour outlet stream is blocked (frequency = 0.008).\u00a0 Pressure relief valve fails <\/strong>happens when any one of the following circumstances happens: <strong>valve leaking (frequency=0.023)<\/strong>, <strong>valve calibrated at a wrong pressure (frequency=0.005)<\/strong>, or <strong>contaminants causing the valve to stick (frequency = 0.056)<\/strong>.<\/p>\n<\/div>\n<\/div>\n<div class=\"textbox\">\n<h3>Solution<\/h3>\n<p>a) The process stream in the heat exchanger will not be sufficiently cooled down, so the conversion to nitric acid will be lower, decreasing the concentration of the product in the absorber.<br \/>\nThere will not be enough flow to absorb the heat in the boiler, which will lead to a temperature increase, pressure build-up and potential explosion of the gas in the boiler.<br \/>\nb)<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-2147\" src=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-absorber-fault-tree-300x186.png\" alt=\"\" width=\"702\" height=\"436\" srcset=\"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-absorber-fault-tree-300x186.png 300w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-absorber-fault-tree-1024x634.png 1024w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-absorber-fault-tree-768x476.png 768w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-absorber-fault-tree-65x40.png 65w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-absorber-fault-tree-225x139.png 225w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-absorber-fault-tree-350x217.png 350w, https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-content\/uploads\/sites\/1010\/2020\/07\/Capture-absorber-fault-tree.png 1154w\" sizes=\"auto, (max-width: 702px) 100vw, 702px\" \/><\/p>\n<\/div>\n<p>&nbsp;<\/p>\n<\/div>\n","protected":false},"author":948,"menu_order":4,"comment_status":"closed","ping_status":"closed","template":"","meta":{"pb_show_title":"on","pb_short_title":"","pb_subtitle":"","pb_authors":[],"pb_section_license":""},"chapter-type":[],"contributor":[],"license":[],"class_list":["post-2101","chapter","type-chapter","status-publish","hentry"],"part":1643,"_links":{"self":[{"href":"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-json\/pressbooks\/v2\/chapters\/2101","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-json\/pressbooks\/v2\/chapters"}],"about":[{"href":"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-json\/wp\/v2\/types\/chapter"}],"author":[{"embeddable":true,"href":"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-json\/wp\/v2\/users\/948"}],"replies":[{"embeddable":true,"href":"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-json\/wp\/v2\/comments?post=2101"}],"version-history":[{"count":20,"href":"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-json\/pressbooks\/v2\/chapters\/2101\/revisions"}],"predecessor-version":[{"id":2728,"href":"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-json\/pressbooks\/v2\/chapters\/2101\/revisions\/2728"}],"part":[{"href":"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-json\/pressbooks\/v2\/parts\/1643"}],"metadata":[{"href":"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-json\/pressbooks\/v2\/chapters\/2101\/metadata\/"}],"wp:attachment":[{"href":"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-json\/wp\/v2\/media?parent=2101"}],"wp:term":[{"taxonomy":"chapter-type","embeddable":true,"href":"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-json\/pressbooks\/v2\/chapter-type?post=2101"},{"taxonomy":"contributor","embeddable":true,"href":"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-json\/wp\/v2\/contributor?post=2101"},{"taxonomy":"license","embeddable":true,"href":"https:\/\/pressbooks.bccampus.ca\/chbe220\/wp-json\/wp\/v2\/license?post=2101"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}