3. Ideal and Real Gasses

3.2 Real gas and compressibility factor

The [latex]P-v-T[/latex] relation of a real gas doesn’t obey the ideal gas EOS. For a gas at a given range of pressures and temperatures, we may calculate its compressibility factor to evaluate the suitability of the ideal gas EOS for the given condition.

 

The compressibility factor is a dimensionless correction factor to account for the deviation of the real gas behaviour from the “ideal” gas model. It is defined as

 

[latex]Z = Pv/RT[/latex]     or     [latex]Pv = ZRT[/latex]

where

[latex]Z[/latex]: compressibility factor, dimensionless

[latex]v[/latex]: specific volume, in m3/kg

[latex]T[/latex]: absolute temperature, in K

[latex]P[/latex]: pressure, in kPa or Pa

[latex]R[/latex]: gas constant, in kJ/kgK or J/kgK

The compressibility factor of an ideal gas is exactly one. For real gases, the compressibility factor may be very different from one. Figures 3.2.1 and 3.2.2 illustrate the compressibility factors of hydrogen and nitrogen, respectively, over a range of pressures and temperatures. It can be seen that the compressibility factor changes with both pressure and temperature. As the pressure approaches zero, the compressibility factor tends to converge to one. In other words, a real gas may behave like an ideal gas at “low” pressures regardless of its temperature.

 

From Figures 3.2.1 and 3.2.2, it can be seen that the compressibility charts for different gases may vary largely. It is therefore more practical to use a generalized compressibility chart, as shown in Figure 3.2.3, where the pressures and temperatures are normalized with respect to the critical pressure and critical temperature of a gas. The reduced pressure [latex]P_{r}[/latex] and reduced temperature [latex]T_{r}[/latex] are defined as

 

[latex]P_{r}=P / P_{crit}[/latex]

[latex]T_{r}=T / T_{crit}[/latex]

where

[latex]P[/latex]: pressure, in kPa or Pa
[latex]P_{crit}[/latex]: critical pressure, in kPa or Pa. [latex]P_{crit}[/latex] and [latex]P[/latex] must have the same unit.
[latex]P_{r}[/latex]: reduced pressure, dimensionless
[latex]T[/latex]: absolute temperature, in K
[latex]T_{crit}[/latex]: critical temperature, in K
[latex]T_{r}[/latex]: reduced temperature, dimensionless

The compressibility factor is thus plotted as a function of [latex]P_{r}[/latex] and [latex]T_{r}[/latex]. The generalized compressibility chart can be viewed as a graphical representation of the gas behaviour over a wide range of pressures and temperatures. It is valid for many substances, especially those that have simple molecular structures. From Figure 3.2.3, it can be seen that the smallest compressibility factor occurs at the critical point, [latex]P_{r}=1[/latex] and [latex]T_{r}=1[/latex]. This indicates that a real gas deviates significantly from the ideal gas behaviour near its critical point. As [latex]P_{r}\to 0[/latex] or [latex]T_{r}\ge 2[/latex], the compressibility factor [latex]Z\to 1[/latex]. In other words, a real gas behaves like an ideal gas at “low” pressures and “high” temperatures.

 

 

Compressibility factor of hydrogen
Figure 3.2.1 Compressibility factor of hydrogen
Compressibility factor of nitrogen
Figure 3.2.2 Compressibility factor of nitrogen
Lee-Kesler simple fluid compressibility factor as a function of reduced pressure and reduced temperature
Figure 3.2.3 Lee-Kesler simple fluid compressibility factor

Typically, thermodynamic tables or real-gas EOS are used for evaluating the relation of pressure, temperature, and specific volume of real gases. If neither tool is available, the generalized compressibility chart may be used instead as a fast and reasonably accurate tool, especially for substances with simple molecular structures. Below is the procedure of how to use the generalized compressibility chart, followed by examples.

  1. Find the critical pressure, [latex]P_{crit}[/latex], and critical temperature, [latex]T_{crit}[/latex], of a substance from Appendix E
  2. Calculate the reduced pressure, [latex]P_{r}[/latex], and reduced temperature, [latex]T_{r}[/latex], of the substance at the given condition
  3. Estimate the compressibility factor, [latex]Z[/latex], from Figure 3.2.3.
  4. Apply [latex]Pv = ZRT[/latex] to determine the unknown specific volume (if needed)

 

Example 1

Find the compressibility factor of the following substances at the given conditions. Is it reasonable to treat them as ideal gases at the given conditions?

  1. Methane at -50oC, 4.1 MPa
  2. Ammonia at 600oC, 500 kPa

Solution

1. Methane at -50oC, 4.1 MPa

First, find the critical properties of methane from Table E1.

[latex]T_{crit}= 190.6 \ \rm{K}[/latex],  [latex]P_{crit}=4.60 \ \rm{MPa}[/latex]

Second, calculate the reduced temperature and reduced pressure.

[latex]T_r = \displaystyle \frac{T}{T_{crit}} = \frac{273.15 - 50}{190.6} = 1.17[/latex]

[latex]P_r = \displaystyle \frac{P}{P_{crit}} = \frac{4.10}{4.60} = 0.89[/latex]

From Figure 3.2.3, the compressibility factor [latex]Z \approx0.78 << 1[/latex]; therefore, methane at the given condition cannot be treated as an ideal gas.

 

2. Ammonia at 600oC, 500 kPa

First, find the critical properties of ammonia from Table E1.

[latex]T_{crit}= 405.4 \ \rm{K}[/latex], [latex]P_{crit}= 11.34 \ \rm{MPa}[/latex]

Second, calculate the reduced temperature and reduced pressure.

[latex]T_r = \displaystyle \frac{T}{T_{crit}} = \frac{273.15 + 600}{405.4} = 2.15[/latex]

[latex]P_r = \displaystyle \frac{P}{P_{crit}} = \frac{0.5}{11.34} = 0.04[/latex]

From Figure 3.2.3, the compressibility factor [latex]Z \approx 1[/latex]; therefore, ammonia can be treated as an ideal gas at the given condition. Note that the reduced temperature of ammonia is greater than 2 and the reduced pressure is very small, indicating the given state is far away from the critical point.

 

Example 2

Calculate the specific volume of steam at 3 MPa, 350oC by using three methods: (1) superheated water vapour table, (2) ideal gas EOS, and (3) compressibility factor. How accurate is each of the methods?

 

Solution

Method 1: use the steam table.

From Table A2: P=3 MPa and T=350oC, therefore, v=0.09056 m3/kg

Method 2: use the ideal gas EOS alone

From Table G1: R=0.4615 kJ/kgK for steam.

[latex]\because Pv = RT[/latex]

[latex]\therefore v = \displaystyle\frac{RT}{P} = \displaystyle\frac{0.4615 \times (273.15 + 350)}{3000} = 0.09586\ \rm{m^3/kg}[/latex]

The relative error in comparison to method 1 is

[latex]error \% = \displaystyle\frac{| 0.09586 - 0.09056 |}{0.09056}\times100\% = 5.85\%[/latex]

Method 3: use the ideal gas EOS corrected by the compressibility factor

From Table E1: Pcrit=22.06 MPa, Tcrit=647.1 K for water.

Calculate the reduced pressure and reduced temperature at the given condition:

[latex]P_r = \displaystyle\frac{P}{P_{crit}} = \displaystyle\frac{3}{22.06} = 0.136[/latex]

[latex]T_r = \displaystyle\frac{T}{T_{crit}} = \displaystyle\frac{273.15 + 350}{647.1} = 0.963[/latex]

Estimate the compressibility factor from Figure 3.2.3: [latex]Z \approx0.94[/latex]

Calculate the specific volume at the given condition by incorporating the compressibility factor

[latex]\because Pv = ZRT[/latex]

[latex]\begin{align*} \therefore v = \displaystyle\frac{ZRT}{P} &= \displaystyle\frac{0.94\times0.4615\times(273.15 + 350)}{3000} \\&= 0.09011  \ \rm{m^3/kg}   \end{align*}[/latex]

The relative error in comparison to method 1 is

[latex]error \% = \displaystyle\frac{| 0.09011 - 0.09056 |}{0.09056}\times100\% = 0.497\%[/latex]

Comment:

Method 1 gives the most accurate value for specific volume among the three methods, as the steam table is specific for water vapour at different pressures and temperatures. Method 2 assumes steam as an ideal gas. This method is easy to use but gives the least accurate result. Method 3, by correcting the ideal gas EOS with the compressibility factor, improves the accuracy of the calculation.

Practice Problems

Media Attributions

definition

License

Icon for the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License

Introduction to Engineering Thermodynamics Copyright © 2022 by Claire Yu Yan is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License, except where otherwise noted.

Share This Book